Open Access
2014 Study on the Characteristics of Electromagnetic Noise of Axial Flux Permanent Magnet Synchronous Motor
Wei Wang, Hang Wang, Hamid Reza Karimi
Abstr. Appl. Anal. 2014(SI02): 1-8 (2014). DOI: 10.1155/2014/764105

Abstract

The normal electromagnetic force distribution in stator system of axial flux permanent magnet synchronous motor (PMSM) has been thoroughly analyzed in this paper. The main composition of force wave causing vibration and noise has been proposed, and at the same time a calculation method of stator natural frequency of axial flux PMSM has been raised. Through this method electromagnetic force wave, natural frequency, vibration response, and electromagnetic noise of a 15 kW axial flux PMSM with 22 poles and 24 slots have been calculated; calculations and measured values are consistent by comparison. The noise sources of axial flux PMSM have been found in this paper, which provides the theoretical support for the suppression of electromagnetic noise of axial flux PMSM.

Citation

Download Citation

Wei Wang. Hang Wang. Hamid Reza Karimi. "Study on the Characteristics of Electromagnetic Noise of Axial Flux Permanent Magnet Synchronous Motor." Abstr. Appl. Anal. 2014 (SI02) 1 - 8, 2014. https://doi.org/10.1155/2014/764105

Information

Published: 2014
First available in Project Euclid: 6 October 2014

zbMATH: 07023039
Digital Object Identifier: 10.1155/2014/764105

Rights: Copyright © 2014 Hindawi

Vol.2014 • No. SI02 • 2014
Back to Top